Thank you for purchasing the Ionmax Selah ION360 UV HEPA Air Purifier. The Ionmax Selah can help to improve the indoor air quality in your home or office.

Please read this manual carefully before use to ensure proper usage and save these instructions for future reference.


Purification System

The Pre-Filter, HEPA Filter and Activated Carbon Filter are combined into one easy-to-change filter.

1. Pre-Filter
Traps large particles such as human hair, pet dander and dust particles. Helps to extend the life of the HEPA and Activated Carbon filters.

2.HEPA H11 Filter
Traps up to 95% of allergens and airborne contaminants down to 0.3 microns in size. These allergens include lung damaging dust, mould spores, plant spores, pet dander and pollen.

3. Activated Carbon Filter
Absorbs and neutralises odours and other Volatile Organic Compounds (VOC’s) such as formaldehyde and benzene, as well as other harmful fumes emitted by household products.

4. UV-C Light (254nm)
Destroys 99% microorganisms such as germs, viruses, bacteria and fungi (such as mould toxins).

5. Negative Ions
Improve indoor air quality by combining with dust or reacting with odour molecules and removing them from the air we breathe.

Control Panel

Power Button

Press this button to turn the air purifier on or off.
Note: Press and hold Power Button for 3-5 seconds to reset the Filter Reset Indicator.

Timer Button

The air purifier can be timed to operate for intervals of 2, 4, or 8 hours, stopping automatically when the selected operating time has elapsed.
To select continuous operating mode, press the button repeatedly until all three timer lights are off.

UV/ION Button

Press this button to turn the UV lamp and ION function on or off.

Speed Button

The fan speed of the unit can be adjusted between Low (I), Medium (II), High (III) and Turbo when the unit is in operation.
The corresponding fan speed indicator will light up to indicate the current fan speed.
Note: If Turbo is selected, all the three fan speed indicators will light up.

Operating Instructions

Note: Remove plastic bags from air purifier and filter before first use.

  1. Plug the appliance into a suitable electrical outlet.
  2. Ensure the appliance is placed on a stable, flat and level surface.
    Note: For proper air flow, ensure the appliance is 30cm away from any wall or furniture and ensure that the air inlet and outlet is not blocked.
  3. Press the power button to turn the appliance on.
  4. Change the timer, fan speed, or UV/ION settings if desired (refer to Control Panel description).
  5. Press the power button to turn the appliance off.

Important note: When the unit is not in use, switch it off and unplug it.

Maintenance Instructions

CLEANING THE UNIT

  • Always unplug the power supply before cleaning the unit.
  • Do not put the unit into water or use water to wash it directly.
  • Do not use any corrosive or flammable detergent to clean the unit.
  • Use a soft cloth with mild cleanser to clean the unit, and make sure the unit is completely dry after cleaning.
  • Regularly clean the inside and surface, to prevent dust from gathering.
  • Regularly clean the air intake and air outlet.
  • To maintain or replace filters, see below.

STORAGE INSTRUCTIONS

If the unit will not be in use for a long time, please pack and store it properly:

  • Unplug the power supply of the unit.
  • Clean the filter.
  • Use a soft cloth to clean the air intake and air outlet.

CAUTION

  • Proper use and regular maintenance can ensure efficient operation and extend the life of the unit.
  • Do not attempt to repair or adjust any electrical or mechanical functions on this unit. All servicing should be performed by qualified personnel only.

Filter Replacement

FILTER RESET INDICATOR

When the “FILTER RESET” indicator turns red during operation, it indicates that the 3-in-1 filter needs to be replaced.
Follow the instructions below on replacing the filters.
Note: The 3-in-1 filter can be used for about 6 months if used continuously, but its actual life depends on air quality condition and proper maintenance.

REPLACING THE FILTERS

  1. Ensure the unit is switched off. Turn the unit upside down.
  2. Unscrew and remove the screw cap on the base of the unit.
  3. Remove the base of the unit and remove the old filter.
  4. Replace with a new filter (remove any plastic packaging beforehand).
  5. Reattach the base onto the unit and fasten it with the screw cap.
  6. Position the unit back on to its base.
  7. Press the power button to switch the unit on. Then, press and hold the power button for 5 seconds to reset the “FILTER RESET” indicator light.

FILTER MAINTENANCE

  • The 3-in-1 filter is not washable.
  • Do not use any solutions, brushes or sharp objects to clean the filter, as this can damage it.
  • It can be gently vacuumed using hand tool attachments (no rotating brushes) once a month.